Propellerhead Reason Spécifications Page 162

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 298
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 161
NN-XT SAMPLER
160
Adjusting Parameters
Adjusting Synth Parameters
The synth parameters are the ones that occupy the bulk of the remote editor
panel (see page 157). Changes you make to synth parameters always apply to
all selected zones.
D The panel “only” shows the settings for the zone with edit focus.
More about this below.
D To make adjustments to one zone, select it (which also gives it edit
focus) and adjust the parameter on the front panel.
D To set several zones to the same value, select them and adjust the
parameter.
All zones will be set to the same value for the parameter you adjusted.
Adjusting Group Parameters
Group parameters apply to a group. That is, they are settings that are shared by
all zones in a group.
D To make adjustments to one group, select one or more zones that
belong to the group, and adjust the parameter on the front panel.
D To set several groups to the same value, select at least one zone in
each group you want to adjust, and adjust the parameter.
All groups will be set to the same value. More about this below.
Sample Parameters
About Single and Multiple Parameters
The Sample parameters are divided into two groups: single and multiple, differ-
entiated by color on the front panel:
D Single adjustment parameters can only be applied to one zone at a
time. Adjustments made to these parameters always only apply to
the zone with edit focus.
D Multiple adjustment parameters apply to all selected zones, just
like the synth parameters, as described above.
About “Conflicting” Parameters
Often you will find yourself in a situation where you select multiple zones and pa-
rameter settings differ between them. This is quite normal. For example, you will
often find yourself making adjustments to for example level and filtering to bal-
ance the sound between several samples across the keyboard. However, if you
have multiple selections this can sometimes lead to confusion: Enter the NN-
XT’s “conflicting parameters” indication:
Whenever two or more selected zones have conflicting parameter settings, NN-
XT will notify you about this by showing a small “M” (for multiple) symbol, next to
the parameter.
In this example, Level and Spread have conflicting settings.
D The controls on the panel always show the setting for the zone with
edit focus.
D By clicking your way through the zones within the selection, you
can see the settings for each zone.
D If you adjust a parameter, all selected zones will be set to the same
value for this parameter.
You can put this functionality to good use when checking how a patch has been
created and when checking that your own settings are consistent through the
various zones.
Copying parameters between zones
You can easily copy parameter settings from one zone to any number of other
zones. Proceed as follows:
1. Select all the zones you want to involve in the operation.
By this we mean the zone with the settings you wish to copy, and the zone(s)
to which you want to copy the settings.
2. Make sure the zone that contains the settings you want to copy has
edit focus.
3. Pull down the Edit menu or the NN-XT context menu and select
“Copy Parameters to Selected Zones”.
All the selected zones will now get the exact same parameter settings.
! Observe that this only applies to the synth parameters (see page
175). Sample parameters (root key, velocity range etc.) can not be
copied.
Single adjustment parameters Multiple adjustment parameters:
Vue de la page 161
1 2 ... 157 158 159 160 161 162 163 164 165 166 167 ... 297 298

Commentaires sur ces manuels

Vikitvv 04 Jan 2024 | 13:04:50

urenrjrjkvnm

Evabhf 07 Jan 2024 | 16:01:45

Med

Viktoridbv 14 Jan 2024 | 00:33:23

Cinema